P
age
17
- Manual
FA01359-EN
- 03/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CX input
Associate a function with the CX input.
The parameter [C3] appears only if the [Automatic closing] function is active
F2
CX input
OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic
close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive
edges)
C8 = Reclose while opening (sensitive
edges)
CY input
Associate a function with the CY input.
The parameter [C3] appears only if the [Automatic closing] function is active
F3
CY input
OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic
close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive
edges)
C8 = Reclose while opening (sensitive
edges)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
The safety devices test function is always active for wireless safety devices.
F5
Safety devices test
OFF (Default)
1 = CX
2 = CY
4 = CX+CY
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6
Hold-to-run
OFF (Default)
ON