LA250EVK / LA300EVK

en

Swing Gate Operator Installation Manual*

fr

Manuel d‘installation de l‘opérateur de porte battante

nl

Installatiehandleiding draaihekaandrijving

de

Installationshandbuch für Drehtorantriebe

pl

Instrukcja instalacji operatora bramy skrzydłowej

cs

Instalační manuál pro obsluhu křídlové brány

sk

Inštalačný manuál k pohonu krídlovej brány

sl

Priročnik za namestitev upravljalnika krilnih vrat

hu

Swing kapu Üzemeltető Installation Manual

* For GB (UK, NI) specific information on national regulations and requirements

see English part of the manual.

Содержание LA250EVK

Страница 1: ...shandbuch für Drehtorantriebe pl Instrukcja instalacji operatora bramy skrzydłowej cs Instalační manuál pro obsluhu křídlové brány sk Inštalačný manuál k pohonu krídlovej brány sl Priročnik za namestitev upravljalnika krilnih vrat hu Swing kapu Üzemeltető Installation Manual For GB UK NI specific information on national regulations and requirements see English part of the manual ...

Страница 2: ...12 7 6 Programming and Erasing of Remote Controls Radio Accessories and myQ Devices 13 7 7 Advanced Settings 14 7 7 1 Overview Advanced Settings 14 7 7 2 Transmitter Settings 14 7 7 3 Infrared Photocells Settings 14 7 7 4 Input Settings 14 7 7 5 PartialOpeningMotor1 15 7 7 6 Delay Motor 2 in Open Direction 15 7 7 7 Delay Motor 1 in Close Direction 15 7 7 8 Timer to Close 15 7 7 9 Reversal Time aft...

Страница 3: ...d to the gate system This is also obligatory in the process of retrofitting on a manually operated gate Further a handover pack and an inspec tion book must be completed Please read the operating instructions and especially the precautions The following symbols are placed in front of instructions to avoid personal injury or damage to property Read these instructions carefully Warnings Symbols The ...

Страница 4: ...le locations The gate opener should ONLY be used if the user can see the entire gate area and is assured that it is free of obstacles and the gate operator is set correctly No one may pass through the gate area while it is moving Children must not be allowed to play in the vicinity of the gate The full protection against potential crushing or entrapment must work immediately when the drive arms ar...

Страница 5: ...x Release Key 4x Release Key 4x Installation Manual Installation Manual Remote Control 2x Control Box M10x30 Screws 4x Gate Mounting Bracket 2x Gate Mounting Bracket 2x Circlip 4x Circlip 2x Circlip pin 4x Circlip pin 2x Washer and Bolt 2x LA250EVK LA300EVK LA250EVK LA300EVK 1 Motor 1 2 Motor 2 3 Control board 4 Post bracket 5 Gate bracket 6 Infrared photocells 7 Flashing lamp 1 2 6 4 4 5 3 5 6 7 ...

Страница 6: ... installation of the gate operator LA300EVK LA250EVK 1 5 m 250 kg 2 0 m 200 kg 2 5 m 150 kg LA300EVK 2 0 m 300 kg 2 5 m 250 kg 3 0 m 200 kg mm A 100 120 140 160 180 B 100 n a 110 105 105 100 120 110 110 100 95 95 140 100 100 100 90 80 160 95 95 90 85 75 180 90 90 80 75 70 mm A 100 120 140 160 180 B 100 n a 110 105 105 100 120 110 110 100 95 95 140 100 100 100 90 80 160 95 95 90 85 75 180 90 90 80 ...

Страница 7: ...l hard stop Consider the dimensions A and B from Table 1 d Manually open and close the gate to the required positions Ensure the operator arm does not bind and gate is moving smoothly For LA300EVK please ensure that in the OPEN position the trolley is having min 25 mm free space e Make permanent connection of the gate bracket at chosen correct position 4 2 Installation with internal operator hard ...

Страница 8: ...table on page 5 for other settings 1 and 2 are operator internal hardstops 1 2 5 mm 1115 mm Spirit level 61 mm 730 mm with hardstops 750 mm w o hardstops Spirit level 1 2 3 1 x 360 4 1 a 25 mm min 25 mm min 4 1 a 4 1 b 4 1 c LA250EVK LA300EVK LA250EVK LA300EVK 5 MECHANICAL INSTALLATION ...

Страница 9: ...ing must be done by a certified electrician specialist Congratulations Herewith the mechanical installation of your gate ope rator is finished Please proceed with Programming and Basic Settings to be able to start operation Motor 2 Connection NOTE The operator wired to the MOTOR 2 terminal will always open last and close first Consider this for Basic and Advanced Settings see Programming section 1...

Страница 10: ...use IR 1 IR 2 IR 3 SYNC STBY UART LIMIT SW connectors are not used for LA units MOTOR 2 WHT GRN RED MOTOR 1 M M BAT BAT 24V BATTERY POW 24V SPEC 24VDC SYNC STBY UART LIMIT SW E LK FLA COMMAND IR SENSOR EDGE 24V BAT 8 2K SAFETY EDGE NC NO NO Stop Total Open Partial Open E LOCK MAG LOCK LAMP 1 FLASH LAMP SE SE GND GND IR3 IN3 IN2 IN1 IR2 IR1 L L N N PE AC 230V IN CTRL GND 12V TX RX 5V OP CL 24V exte...

Страница 11: ...on for 5 seconds to enter the menu AP on the display indicates the first available function in menu 2 Use and buttons to navigate between the functions 3 Press P button to select the required function 4 The default setting or previously programmed value will appear This will be indicated by flashing of value on display 5 Use or buttons to select the required value Press P button to confirm selecti...

Страница 12: ... Defines movement direction of the Motor 2 Not available for one motor application 7 4 3 Direction Motor 2 Settings Motor 2 is moving in closing direction Motor 2 is moving in opening direction Available Learning methods Before starting a Learning phase ensure that 1 Other Basic Settings are completed 2 Internal external hard stops are installed for swing gates 3 First movement will be in CLOSE di...

Страница 13: ...ing 2 actions are not used Following settings are programmed during Advanced Learning mode 1 Travel length from FULL CLOSED to FULL OPEN position 2 Opening and closing force for each motor 3 Starting positions of the Soft Stops 4 Wing delay in opening and closing position is 2 seconds Shall you need to change the delay please go to Advanced Settings Delay Motor 2 d0 and Delay Motor 1 dC NOTE To st...

Страница 14: ...f IRs is mandatory for myQ operation 2 Create an account Download the free myQ App from App Store or Google Play Store and create an account If you already have an account use your username and password 3 Register the internet gateway Enter the Serial Number located on the bottom of the internet gateway when prompted 4 Add myQ devices To add your gate operator to the registered gateway follow the ...

Страница 15: ...function defines the way Input commands from external accessories are executed Each of the 3 Inputs can be programmed individually NOTE Under settings 01 02 and 03 TTC timer will be overridden by an Input command and will CLOSE the gate Under setting 06 active TTC timer count down will be re set to start again by an Input command IR active on CLOSE movement If IR beam is obstructed gate re verses ...

Страница 16: ... the IR beams are interrupted the TTC timer shall re start 2 seconds reversal and Stop Reversal back up to the end limit position Default During Closing movement upon impact gate reverses up to Open position During Opening movement upon impact gate reverses for 2 seconds and stops 7 7 9 Reversal Time after Impact Reversal time after impact function defines reversal behavior after obstacle obst ruc...

Страница 17: ...reached If PF Function Pre Flashing is active then 4 second pre flashing will be added to the set time To reset counter after maintenance is done it will be enough to program the cycles one more time deactivated Default 1 second activated 2 seconds activated 7 7 10a Relief Motor 1 for E Lock Relief Motor 1 for E Lock function enables to briefly push Motor 1 in CLOSE direc tion before engaging e lo...

Страница 18: ...ttings All settings apart from Radio Memory will be deleted See page 18 P S P S P S P S III I I I III I I I 2 sec III I I I or or 7 PROGRAMMING 7 7 15d Force Motors 1 and 2 in Open and Close Directions Force Motor 2 in OPEN Direction Force Motor 1 in OPEN direction allows force adjustment on top of force set during the Learning phase Password must be entered to access this function Force Motor 2 i...

Страница 19: ...will go into Stand by mode and is ready to work There are also other ways to exit the programming and save settings Press and hold P button for 5 seconds Wait 3 minutes after the last changes in the programming for automatic exit no reset Default reset to the factory default settings 7 PROGRAMMING 8 BATTERY BACKUP Battery Back Up Mode 2 Optional 12V 2 2Ah lead batteries SKU 490EV optional not incl...

Страница 20: ...ety edge is pressed 3 Check if safety edge is pressed E5 Press transmitter but no gate movement 1 STOP swtich is open 1 Check if STOP switch is open or damaged 2 STOP switch is not connected 2 Check if STOP switch is disconnected If yes then reconnect STOP switch or change the respective Input setting to other value E7 Press transmitter but no gate movement Control board amplifier for Motor 1 fail...

Страница 21: ...der with hard stops Operating Radio Frequency Sending power MHz RX 433MHz 433 30MHz 433 92MHz 434 54MHz RX 868MHz 868 30MHz 868 95MHz 869 85MHz TX 865 125MHz 865 829MHz 866 587MHz 10mW Code Security 2 0 Max nr of remotes 180 Max nr of keypads 4 Max nr of myQ devices 16 External accessory power 24VDC max 500mA Flahing lamp connector 24VDC max 500mA E Lock Magnetic lock conenctor 24VDC max 500mA Ext...

Страница 22: ...our statutory rights are not affected by this manufacturer s warranty Please see www liftmaster eu for terms of warranty Our electrical and electronic equipment may not be disposed of with household waste and must be disposed of after use properly in accordance with WEEE Direc tive EU 2012 19 EU GB UK NI SI 2012 nr 19 on waste electrical and electronic equipment in order to ensure that materials a...

Страница 23: ...Chamberlain GmbH Saar Lor Lux Str 19 66115 Saarbrücken Germany WEEE Reg Nr DE66256568 www liftmaster eu info liftmaster eu 2021 all rights reserved 114A5438 ...