P
age
16
- Manual
FA01359-EN
- 03/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
PROGRAMMING
Programming button functions
1
ESC button
The ESC button is used to perform the operations described below.
Exit the menu
Delete the changes
Go back to the previous screen
2
< > buttons
The <> buttons are used to perform the operations described below.
Navigate the menu
Increase or decrease values
3
ENTER button
The ENTER button is used to perform the operations described below.
Access menus
Confi rm choice
During movement, outside the menu, the ESC key stops the gate and the <> keys open and close the gate.
Getting started
Once the electrical connections have been made, proceed with commissioning. Only skilled and qualifi ed staff
may perform this operation.
Make sure that there are no obstacles in the way.
Start programming with the functions indicated below.
A1 Motor type
F46 Number of motors
A3 Travel calibration
Complete programming and check the warning and safety devices are working properly.
After powering up the system, the fi rst manoeuvre is always to open the gate Wait for the manoeuvre to be
completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or
vibrations, or unexpected behaviour in the system.
Functions menu
Total stop
Stop the gate and exclude automatic closing. Use a control device to resume movement.
F1
Total stop
OFF (Default)
ON