Determining the end-of-travel points with micro limit switches
A
Rod for determining the closing end-of-travel point
C
Rod for determining the opening end-of-travel point
M
Micro limit switches
The micro switches are positioned at the far ends of the travel range.
To move the microswitch 10 mm in either direction, turn the rod 20 times.
A
C
Determining the opening end-of-travel points
Perform the operations on both gearmotors.
Release the gearmotor.
Manually open the leaf to the desired point.
Disconnect the 9-pole terminal board.
Connect the multimeter set to check continuity to the Rc-Rc terminals (NC contact); a buzzer will sound on the multimeter.
Turn the shaft (C) ANTICLOCKWISE to determine the opening travel end point, until the Rc-Rc contact opens and the multimeter stops buzzing.
Leave the rod nut loose to determine the end-of-travel points.
M N
Rc Rc
Ra Ra + E -
Ω
V