Opening slowdown point for M2
Set the opening slowdown starting point for M2 (percentage of the total travel).
F41
Opening slowdown point
1% to 60% (Default 25%)
Closing slowdown point for M2
Set the closing slowdown starting point for M2 (percentage of the total travel).
F42
Closing slowdown point
1% to 60% (Default 25%)
Opening approach point for M2
Set the opening approach starting point for M2 (percentage of the total travel).
F43
Opening approach point
1% to 10% (Default 10%)
Closing approach point for M2
Set the closing approach starting point for M2 (percentage of the total travel).
F44
Closing approach point
1% to 10% (Default 10%)
Number of motors
Set the number of motors that control the gate.
F46
Number of motors
OFF = M1+M2 (Default)
ON = M2
Managing the serial connection
Enable CRP operation.
F49
Managing the serial connection
OFF
3 = CRP (Default)
Save data
Save user data, timings and confi gurations to the memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is
inserted into the control board.
F50
Save data
OFF (Default)
ON
Read data
Upload user data, timings and confi gurations from the memory device (memory roll or USB key).
The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is
inserted into the control board.
F51
Read data
OFF (Default)
ON