Peripheral number
Assign a unique identifi cation code (CRP address) to the control board. It is used where there are multiple operators connected
to the same communication BUS with CRP protocol.
F56
Peripheral number
from 1 to 255
Communication speed
Set the communication speed of the remote connection system.
F63
Communication speed
0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
RIO ED T1
Associate one of the available functions with a wireless safety device.
The function only appears if there is an interface board for wireless devices.
F65
RIO ED T1
OFF (Default)
P0 = It stops the gate and excludes
automatic closing. Use a control device
to resume movement.
P7 = Reopen while closing.
P8 = Reclose while opening.
RIO ED T2
Associate one of the available functions with a wireless safety device.
The function only appears if there is an interface board for wireless devices.
F66
RIO ED T2
OFF (Default)
P0 = It stops the gate and excludes
automatic closing. Use a control device
to resume movement.
P7 = Reopen while closing.
P8 = Reclose while opening.