Automatic closing after either partial or pedestrian opening.
Set the time before automatic closure is activated, after a partial opening command has been performed or after the
photocells have caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a
complete stop, or during a power outage.
F20
Automatic closing after either
partial or pedestrian opening.
OFF (Default)
From 1 to 180 seconds
Pre-fl ashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-fl ashing time
OFF (Default)
1 to 10 seconds
Operating time
Set the gearmotor working time during opening and closing.
F22
Operating time
5 to 180 seconds (Default 120)
M1 opening delay time
It adjusts the delay with which the fi rst leaf must start the opening manoeuvre with respect to the second leaf.
F23
M1 opening delay time
0 to 10 seconds (Default 2)
M2 closing delay time
It adjusts the delay with which the second leaf must start the closing manoeuvre with respect to the fi rst leaf.
F24
M2 closing delay time
0 to 25 seconds (Default 5)
Thrust time
Adjust the gearmotor closing thrust time after an opening or closing command.
F26
Thrust time
1 to 2 seconds (Default 1)
Electric lock time
Adjust the electric lock release time after an opening or closing command.
F27
Electric lock time
1 to 4 seconds (Default 1)
Gate travel speed
Set the travel speed (percentage of maximum speed).
F28
Gate travel speed
40% to 100% (Default 100%)
Slowdown speed
Set the slowdown speed (percentage of maximum speed).
F30
Slowdown speed
15% to 60% (Default 50%)