Connecting the safety devices (i.e. the safety test)
At each opening and closing command, the control board checks
the effi cacy of the safety devices (such as, photocells).
Any anomalies will inhibit all commands.
Enable this function when programming.
LED 2
LED 1
⚠
Only program functions when the operator is stopped.
When programming is finished, set all Dip-switches to OFF.
You can save up to 25 users.
To check whether a function is enabled or disabled, set the DIP switches in the position that corresponds
to the function and check which of the two LEDs is blinking.
LED 1 -
the function is disabled.
LED 2 -
the function is enabled.
PROG button
FUNCTIONS PROGRAMMING
LED (PRG)