Chapter 4: Legal and regulatory information
Compliance with safety standards
Page 4-29
Band
Antenna
P burst
(W)
P
(W)
G
(dBi)
S
(W/ m
2
)
d
(m)
5.4 GHz
Omni-directional 0.036
0.042
20.0 (13.0 dBi)
9.39
0.07
90° sector
0.014
0.017
50.1 (17.0 dBi)
9.39
0.07
2ft directional flat plate
0.001
0.001
707.9 (28.5 dBi)
9.39
0.07
2ft directional parabolic
0.001
0.001
707.9 (28.5 dBi)
9.39
0.06
5.8 GHz
Omni-directional
0.24
0.28
20.0 (13 dBi)
9.69
0.20
90° sector
0.10
0.12
50.1 (17 dBi)
9.69
0.20
2ft directional flat plate
0.54
0.63
707.9 (28.5 dBi)
9.69
1.67
4ft directional parabolic
0.54
0.63
3388.4 (35.3 dBi)
9.69
4.82