Chapter 3: System planning
Site planning
Page 3-11
Note
A restricted access location is defined (in EN 60950-1) as one where access may only
be gained by use of a tool or lock and key, or other means of security, and access is
controlled by the authority responsible for the location. Access must only be gained
by persons who have been instructed about the reasons for the restrictions applied to
the location and about any precautions that must be taken. Examples of permissible
restricted access locations are a lockable equipment room or a lockable cabinet.
ODU wind loading
Ensure that the ODU and the structure on which it is mounted are capable of withstanding the
prevalent wind speeds at a proposed 450 Platform site. Wind speed statistics are available from
national meteorological offices.
The ODU and its mounting bracket are capable of withstanding wind speeds of:
Up to 200 mph (322 kph) for PMP 450m Series – AP 5 GHz
Up to 200 mph (322 kph) for PMP/PTP 450i – all models 5 GHz
Up to 200 mph (322 kph) for PMP/PTP 450 – all models
Up to 200 mph (322 kph) for PMP 450 – Ruggedized
Up to 200 mph (322 kph) for PMP 450i – all models 900 MHz
Up to 90 mph (145 kph) for PMP 450d
Up to 100 mph (161 kph) for 900 MHz antennas
Wind blowing on the ODU will subject the mounting structure to significant lateral force. The
magnitude of the force depends on both wind strength and surface area of the ODU. Wind loading
is estimated using the following formulae:
Force (in kilograms) = 0.1045aV
2
where:
o
“a” is the surface area in square meters, and
o
“V” is the wind speed in meters per second.
Force (in pounds) = 0.0042Av
2
where:
o
“A” is the surface area in square feet, and
o
“v” is the wind speed in miles per hour.
Applying these formulae to the 450 platform at different wind speeds, the resulting wind loadings
are shown in below tables.
Содержание PMP 450d Series
Страница 101: ...Chapter 2 System hardware GPS synchronization Page 2 40 Figure 25 Cluster Management Scenario 1 ...
Страница 125: ...Chapter 3 System planning Typical deployment Page 3 3 Figure 37 Wall installation ...
Страница 126: ...Chapter 3 System planning Typical deployment Page 3 4 Figure 38 Roof installation ...
Страница 127: ...Chapter 3 System planning Typical deployment Page 3 5 Figure 39 GPS receiver wall installation ...
Страница 128: ...Chapter 3 System planning Typical deployment Page 3 6 Figure 40 GPS receiver tower or mast installation ...