User Manual – Rev B
FCS Series II
units.
Notes:
External Trigger input is standard.
External Trigger input and External sync are mutually exclusive.
Units with -LKS (auxiliary) cannot have External Sync.
2.6.1 -HV Option - Supplemental Specifications
Specifications for FCS units with -HV voltage range option installed are same as standard FCS
except where noted below.
Frequency
Range:
45 Hz - 1200 Hz
Voltage:
Ranges (L-N):
Low range
0 - 156 Vrms
High range
0 - 312 Vrms
Current
Model
FCS18-1-HV (single phase)
FCS18-3-HV (three phase)
156 V Range.
115.2 Arms
38.4 Arms
312 V Range.
57.6 Arms
19.22 Arms
Note:
Current derates linearly from 50% of voltage range to 20% of specified current at 10% of
voltage range.
Note:
Current, maximum amps per phase available. For FCS36/2, currents are times two. For
FCS54/3, currents are times three. 35° C ambient max.
Repetitive Peak Current
156 V Range.
325 Apk
108 Apk
312 V Range.
162 Apk
54 Apk
California Instruments
22
Содержание FCS Series II
Страница 4: ...User Manual Rev B FCS Series II California Instruments 4...
Страница 27: ...User Manual Rev B FCS Series II California Instruments 27...
Страница 28: ...User Manual Rev B FCS Series II Figure 3 1 Rear Panel Connector Locations California Instruments 28...
Страница 35: ...User Manual Rev B FCS Series II Figure 3 4 FCS54 3 3 Wiring Diagram Three Phase mode California Instruments 35...
Страница 36: ...User Manual Rev B FCS Series II Figure 3 5 FCS54 3 1 Wiring Diagram Single Phase mode California Instruments 36...
Страница 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Страница 92: ...User Manual Rev B FCS Series II Figure 5 2 Power Amplifier Exploded View California Instruments 92...
Страница 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...
Страница 109: ...User Manual Rev B FCS Series II Figure 7 1 Front panel location Figure 7 2 Fuse Locations California Instruments 109...
Страница 118: ...User Manual Rev B FCS Series II ure 8 4 Voltage Modulation Frequency characteristics Fig California Instruments 118...