Operating Your Spa
Page 24
2006 Portable Spa Owner's Manual
LTR20061000, Rev. A
Sn
Sensor (Spa is shut down). The high limit or water temperature sensors are not working
correctly. Call your dealer or service organization.
HL
A difference in readings between temperature sensors has been detected indicating a
possible water flow problem. Make sure spa is filled to proper level and that pumps are
primed (water is flowing). Also check to make sure filter cartridges are clean. If
message does not reset, call your dealer or service organization.
LF
This will display on the 5
th
occurrence of the “HL” message in 24 hours indicating a
persistent flow problem. The heater will be shut down but other functions will continue
to operate. Follow “HL” message actions then press any button to reset.
dr
Insufficient water flow through the heater has been detected. Spa will be shut down for
15 minutes. Check water level and fill spa if water level is low. Make sure pumps are
primed (water is flowing) and filter cartridges are clean. Press any button to reset or wait
15 minutes and spa will automatically reset. If message does not reset, call your dealer or
service organization.
dY
Insufficient water level detected in heater. This will display on the 3
rd
occurrence of “dr”
message. Follow directions for “dr” message and press any button to reset spa. Spa will
not automatically reset when “dY” is displayed.
Sf
Safety Suction System (Spa is shut down). The display will show “Sf” as soon as the
vacuum switch closes. All functions will turn off and the system will be disabled until a
panel button is pressed.