background image

Spa Owner’s

Manual

“Trend Setting Innovations Since 1973”

This Manual Contains

IMPORTANT SAFETY

INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

“SAVE THESE INSTRUCTIONS”

Smart S-3 & Genius G-2.5 & G-3 Series

Summary of Contents for Genius G-2.5

Page 1: ...Spa Owner s Manual Trend Setting Innovations Since 1973 This Manual Contains IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Smart S 3 Genius G 2 5 G 3 Series...

Page 2: ...2 5 and G 3 Dip Switch Configuration 11 Conversion 50 amp to 30 amp Circuit 11 G 2 5 Control Console 13 G 3 Control Console 14 Heating Modes and Other Features 15 Display Messages 16 FILTERS Skim Fil...

Page 3: ...7 Danger Risk of Injury The suction fittings in this spa are sized to match the specific water flow created by the pump Should the need arise to replace the suction fittings or the pump be sure that...

Page 4: ...36 6 C The symptoms of hyperthermia include 1 dizziness 2 fainting 3 drowsiness 4 lethargy and 5 increase in the internal body temperature The effects of hyperthermia include 1 unawareness of impendi...

Page 5: ...ensed electrician READ ALL SAFETY INSTRUCTIONS See pages 1 and 2 for other safety requirements and instructions 3 ChildproofYour Spa Plan for limiting access of children Precautions such as self closi...

Page 6: ...use your spa for a period of time it may be impossible for the freeze protect system to fully protect your spa When severe conditions threaten we strongly recommend that you have the unit drained and...

Page 7: ...sconnect Switch See National Electric Code Article 680 42 680 12 WARNING THIS G F C I PLUG PROVIDES GROUND FAULT PROTECTION FOR THE SPA AND SHOULD NEVER BE REMOVED ALTERED OR DISABLED FOR ANY REASON T...

Page 8: ...INTERRUPTER Should a G F C I circuit test fail immediately disconnect the power plug and contact a certified licensed electrician to diagnose and correct the problem Your Leisure Bay Spa has a factor...

Page 9: ...PAS ARE NOT EQUIPPEDWITH A 240V G F C I OR A DISCONNECT SWITCH A G F C I SHOULD BE INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN OUTDOOR LOAD CENTER The addition of an outdoor load center such as a Si...

Page 10: ...S SPAS ARE NOT EQUIPPEDWITH A 240V G F C I OR A DISCONNECT SWITCH A G F C I SHOULD BE INSTALLED BY A CERTIFIED LICENSED ELECTRICIAN OUTDOOR LOAD CENTER PROVIDES BOTH The addition of an outdoor load ce...

Page 11: ...OUND WHT NEUTRAL RED HOT BLK HOT RED HOT WHT GRN GROUND WHT BLK HOT GRN GROUND Front View of G F C I Square D Bottom View of G F C I Square D RED HOT BLK HOT WHT WHT BLK HOT WHT RED HOT GRN WHITE NEUT...

Page 12: ...ormally off 2 In ON position Wide custom Serial Standard Panel In OFF position Generic Serial Standard Panel 3 N A 4 Aux Freeze must be OFF 5 In ON position Two speed pump 1 when in Circ Mode A9 On In...

Page 13: ...ed pump 1 when in Circ Mode A9 On 6 In ON position 50Hz operation In OFF position 60Hz operation 7 In ON position Blower is enabled In OFF position Blower is disabled 8 In ON position temperature is d...

Page 14: ...to turn the pump on and off If left running the pump automatically will turn off after 15 minutes Freeze Protection If the high limit sensor detects 44 F at the heater then all the equipment automatic...

Page 15: ...turn the pump on and off If left running the pump automatically will turn off after 15 minutes Freeze Protection If the high limit sensor detects 44 F at the heater then all the equipment automatical...

Page 16: ...the pump 1 or 2 on and off If left running the pumps automatically will turn off after 15 minutes Freeze Protection If the high limit sensor detects 44 F at the heater then all the equipment automatic...

Page 17: ...cide to use either the Economy or Sleep Modes you may program your heater to operate two times per day 12 hours apart for durations of 2 4 6 8 or 12 FC hours Note setting the spa to the FC level will...

Page 18: ...pability of the spa will not reset automatically you may press any button to reset Check water level in spa Refill if necessary If water level is okay make sure the pumps have been primed Press any bu...

Page 19: ...ode 2 To remove floating weir and basket rotate it a 1 4 turn counter clockwise 3 Remove the floating weir and basket 4 Remove filter cartridge and wash it with a garden hose inside and out until the...

Page 20: ...Use Maintenance Routine No hard set rules can be established for creation of a spa maintenance program since each individual spa has its own unique location conditions and bather patterns The followin...

Page 21: ...l Alkalinity Alkalinity represents the amount of alkaline minerals in water It is the measure of the buffering capacity or resistance to a change in pH of water It minimizes changes in pH making pH ea...

Page 22: ...000798 10 04...

Reviews: