Operating Your Spa
Page 34
2006 Portable Spa Owner's Manual
LTR20061000, Rev. A
similarly except with the temperature thresholds determined by the switch and without a four-minute delay in
turnoff.
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder.
Message Frequency
Action
Require
rPH
Every 7 days
Test and adjust chemical levels per manufacturer’s
instructions.
rSA
Every 7 days
Test and adjust chemical levels per manufacturer’s
instructions.
rCL
Every 30 days
Remove, clean, and reinstall filter per
manufacturer’s instructions.
rtg
Every 30 days
Test and reset GFCI per manufacturer’s instructions.
Drain and refill spa per manufacturer’s instructions.
rdr
Every 90 days
Drain and refill spa per manufacturer’s instructions.
rCO
Every 180 days
Clean and condition spa cover
rCH
Every 365 days
Install New Bio-Clean™ Filter
WARNING! SHOCK HAZARD!
There are no user serviceable parts. DO NOT attempt service of this control system. Contact your dealer
or service center for service.
Diagnostic Messages
Message Meaning
Action
Required
No message on display. Power has
been cut off to the spa.
The control panel will be disabled until power
returns. Spa settings and time of day will be
preserved for 30 days with a battery back-up; settings
only are preserved until the next power-up on 9800
systems.
OHH
“Overheat” - The spa has shut down.
One of the sensors has detected
118°F at the heater.
DO NOT ENTER THE WATER!
Remove the spa
cover and allow water to cool. Once the heater has
cooled, reset by pushing any button. If spa does not
reset, shut off the power to the spa and call your
dealer or service organization.
OHS
“Overheat” - The spa has shut down.
One of the sensors has detected that
the spa water is 110°F.
DO NOT ENTER THE WATER!
Remove the spa
cover and allow water to cool. At 107°F (41.7°C), the
spa should automatically reset. If spa does not reset,
shut off the power to the spa and call your dealer or
service organization.
ICE
“Ice” - Potential freeze condition
detected.
No action required. The pumps and the blower will
automatically activate regardless of spa status.
Sna
Spa is shut down. The sensor that is
plugged into the Sensor “B” jack is
not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)