ADAL: Diagnostic Alarm Limits
Command
Response
Description
_ADAL_K0
_ADAL_s_a1.min_a1.max_....
_a16.min_a16max
All alarm limits.
_ ADAL_K0_x
_ADAL_s_x.min_x.max
Alarm limits of x
Alarm Limit Numbers and Descriptions
1
Sample Pressure
2
Air Pressure
3
Fuel Pressure
4
Air Inject Pressure
5
Fuel Inject Pressure
6
Filter Temperature
7
Burner Temperature
8
Oven Temperature
9
Cutter Temperature
10
Pump Temperature
11
EPC Coil Sample Voltage %
12
EPC Coil Air Voltage %
13
EPC Coil Fuel Voltage %
14
EPC Coil Air Inject Voltage %
15
EPC Coil Fuel Inject Voltage %
16
Concentration 1 / Concentration 2
AVER: Query Software Version
Command
Response
Description
_AVER_K0
_AVER_s_FMAIN_Z_mm.dd.yyyy_
FUSER_Y_mm.dd.yyyy_OSMSR_
X_dd.mm.yyyy
Z: FMAIN version build number
Y: FUSER version build number
X: OSMSR version build number
dd: Day
mm: Month
yyyy: Year