xGenConnect Installation and Programming Guide
13
• Overriding is not supported with xGenConnect. In case a zone is faulted, one
shall bypass the zone manually before arming or verify the zone and clear the
fault. See user instructions.
• Hold-up zones are not allowed to be set for bypass.
• Zone isolation is not supported.
• EN 50136-2 (Alarm transmission systems and equipment – Part 2:
Requirements for Supervised Premises Transceiver (SPT):
- Upon configuring alarm transmission path and remote connection details,
default user/installer keys shall be changed.
Options Affected by EN 50131 Regulations
EN 50131 Grade 2 Required settings
The following options and values are mandatory for EN 50131-1 Grade 2
regulations.
• Period, 24 h for every path to meet ATS Class 2, 4 h for the IP path to meet
Class 4.
• View Partitions and Control Partitions settings are identical
• Buzzer silent, never
• Quick set, off
• Function keys, all set to None
• User group options, No OP/CL reports option set to No
• Inhibit, set to No for all zones with type Panic, 24H
• Swinger shunt, set to Yes for all zones
• ACK on keypad, set to None for all zones with type Keyswitch
• Entry time, 45 s maximum
• Entry alarms, Instant
• Active, set to No for all schedules.
• Activation, internal and external siren 90 to 900 s
• Delay time, external siren 600 s maximum
• Armed display, 30 s maximum
• Mains reporting delay 10 to 70 s
• User code required, enabled
• Armed display, always
• Alarm list, disabled
• Inhibit includes, all allowed except engineer reset, which must be disabled
• Pending alarms, enabled
• Swinger shunt ≥ 3
• Report restore, on ACK
• Line fault, enabled per path used
• Line fault delay, 0 s
• Partition option to override EN50131-1 Arming Cancelation set to No
• User option not to report open/close events – only with at least one CIE
(Control and Indicating Equipment) in the system
Refer to
xGen Reference Guide
for additional features, accessible at level 3.
Содержание xGenConnect
Страница 1: ...xGenConnect Installation and Programming Guide P N 466 5545 EN REV J ISS 26OCT22...
Страница 4: ......
Страница 12: ...viii xGenConnect Installation and Programming Guide...
Страница 93: ...xGenConnect Installation and Programming Guide 81 Web Page...
Страница 109: ...xGenConnect Installation and Programming Guide 97 Instructions 1 Go to Zone Type...
Страница 117: ...xGenConnect Installation and Programming Guide 105 Webpage...
Страница 156: ...144 xGenConnect Installation and Programming Guide...
Страница 166: ...154 xGenConnect Installation and Programming Guide...