TESTING AND TROUBLESHOOTING
Page 4-2
4.
Verify that the maximum number of stations and maximum cable
lengths for EACH station are not exceeded.
When these checks have been successfully completed for each
connection to the TRMIM-20R, the MIM is ready for normal
operation. If further problems occur, contact Cabletron Systems
Technical Support.
4.2 USING LANVIEW
LANVIEW is Cabletron Systems’ built-in visual diagnostic and status
monitoring system. Using LANVIEW, your network troubleshooting
personnel can quickly scan the LANVIEW LEDs to observe network
status or diagnose network problems, and determine which node or
segment is faulty. The definitions and locations for the front panel
LANVIEW LEDs are illustrated in Figure 4-1.
Figure 4-1. TRMIM-20R LANVIEW LEDs
TRMIM-20R
1
X
7
X
SN
7
8
9
10
1
2
3
4
5
6
ERR
16Mb
A
T
C
H
E
D
A
T
A
T
C
H
E
D
A
T
R I
RO
16 Mb (Yellow)
ON - Ring speed is set for 16 Mbit/sec.
OFF - Ring speed is set for 4 Mbit/sec.
ATTACHED (Green - 10)
ON - This station is inserted into the ring.
OFF - This station is removed from the ring.
ERR (Red)
ON - A hardware error has occurred.
OFF - Normal operation
RING-IN/RING-OUT Port Status (Green - 2)
ON - Respective Ring-In/Ring-Out Port
is in a non-wrap state.
OFF - Respective Ring-In/Ring-Out Port
is in a wrap state