INSTALLATION
3-2
The TRBMIM-T can be installed into any MMAC MIM slot, as described
in Section 2.1. Perform the following tasks before you install the
TRBMIM-T:
•
Specify the ring speed for the FNB and bridge Station port interfaces
•
Specify the operational mode (Bridge-Only or Bridge/Management)
•
Enable the NVRAM backup battery
If you want to setup the bridge Station port before you install the
TRBMIM-T, see Chapter 4 for instructions.
To install the TRBMIM-T:
1. Loosen the fastening knobs on the protection panel covering the slot
into which you want to install the TRBMIM-T, and then remove the
panel as shown in Figure 3-1.
Figure 3-1 Removing a Protection Panel
!
C AUT IO N
To protect the MMAC, always fasten protection panels over
empty slots and also install the security bar. Call your Cabletron
Systems representative if you want to order a MMAC security
bar.
TRMIM-22
TRMM
TRMIM-12
Protection Panel
MMAC-M8FNB
Fastening
Knob
TRBMIM-T BOOK Page 2 Tuesday, July 2, 1996 10:35 AM