MONITORING AND TROUBLESHOOTING
5-2
5.1.1 Describing System LEDs
System LEDs convey information about the status of system hardware
and software elements.
BOK (Board Okay)
The BOK LED indicates the following operational conditions:
Solid Green
The TRBMIM-T is booting, is running system
initialization tests.
Blinking
Green
The TRBMIM-T has successfully completed
system initialization tests, is ready for normal
operation.
Off
The MMAC is powered off, or the TRBMIM-T
is not connected to the MMAC power bus, or
the TRBMIM-T has not initialized and has
failed to start up.
ERR (Error)
The ERR LED indicates the following operational conditions:
Off
The TRBMIM-T is operating normally.
Solid Red
The TRBMIM-T has detected a possible
hardware failure.
Flashing Red
The TRBMIM-T has detected a beaconing
condition while operating in the
Bridge/Management mode.
Try reinserting the TRBMIM-T in the MMAC or resetting the
TRBMIM-T to resolve the problem indicated by a solid red ERR LED. If
that does not resolve the problem, call Cabletron Systems Technical
Support Department for assistance.
TRBMIM-T BOOK Page 2 Tuesday, July 2, 1996 10:35 AM
Содержание TRBMIM-T
Страница 1: ...TRBMIM T TOKEN RING BRIDGE MANAGEMENT MODULE USER S GUIDE BOOKTITLE2 OPTIONAL ...
Страница 2: ......
Страница 8: ...NOTICE vi ...
Страница 26: ...INTRODUCTION 1 16 ...
Страница 38: ...REQUIREMENTS AND SPECIFICATIONS 2 12 ...
Страница 42: ...INSTALLATION 3 4 ...
Страница 50: ...ESTABLISHING THE BRIDGE CONNECTION 4 8 ...
Страница 62: ...MONITORING AND TROUBLESHOOTING 5 12 ...
Страница 66: ...TPIM SPECIFICATIONS A 4 ...
Страница 74: ...INDEX IX 4 ...