Configuration Commands
80-10100000-09
4–13
4.8.5 The User Rate Switch
The default setting is ‘OFF’. The User Rate switch can be used to enable
or disable the transmission of user rate information when a call is made
to the network.
Type:
1> SET USERRATE ON
[CR]
or
1> SET USERRATE OFF
[CR]
to enable or disable the feature. Some TA’s check user rate information,
rejecting the call if they receive the user rate information incorrectly. If
this occurs you should type:
1> USERRATE
[CR]
to see the current setting, then switch the feature ON or OFF as
required, using the syntax above.
4.8.6 LLINE - Options
‘LLINE’ allows the use of the leased line in three different ways when the
KBU 64 has connected the user to the ISDN;
1. Talkwire
2. Loop
3. RXDATA
1> SET LLINE <OPTION>[
CR]
where the option is:
1.
TALKWIRE
- Is the default option, using the line for remote access
(Talkwire link) and integrity checking when set.
2.
LOOP
- By dialling up on the second channel, you can initiate a loop
on the channel to be tested. This allows you to check the return of
your own data (only during back-up mode). During restoral the loop
will always be dropped when the leased line is in use (NORMAL
Mode).