Polling Multiple KBU 64s
80-10100000-09
8–3
8.5 Connecting to a Specific KBU 64 Within a
Polled Environment
Having configured the CONSOLE parameter within your KBU 64 to
POLL, access to the COMMAND port can only be gained by specifying
the polling address of the unit.
For example, from the command console, type:
1> POLL 00001
[CR]
or, where leading zeros exist as above, just:
1> POLL 1
[CR]
to connect you to the COMMAND port of the KBU 64 whose polling
address is set as 00001. Only KBU00001 will respond to the command,
which is reflected by the command line:
00001 1> _
or
00001 2> _
for channel 2
To disconnect the console from this KBU 64’s COMMAND port, type:
00001 1> POLL
[CR]
Alternatively, you can switch to the COMMAND port of another polled
KBU 64 by typing:
00001 1> POLL xxxxx
[CR]
where
xxxxx
represents the polling address of the KBU 64 to
which you will connect.