Configuration Commands
80-10100000-09
4–21
In MANUAL, the factory default mode, you will be notified of a failure on
the link together with it’s cause. You must then initiate Backup manually
from the command line prompt (see
section 6
).
In AUTO, your KBU 64 will automatically backup a failed Kilostream link
on detection of a failure of that link. You will see the cause (e.g. loss of
clocks, data loss or NTU) indicated at the terminal.
Refer to section
4.15
for details of how to configure the timers which
trigger a backup call.
If set to WIN, backup will be enabled and disabled according to the time
of day constraints. You can set this mode by entering the WINDOW
parameter ‘
win’
. This setting only causes restriction of the available
backup origination times, it does not restrict the KBU 64 answering an
incoming call.
4.13.3 Setting the Backup Time Windows
Please note that the ‘time windows’ operation has changed considerably
from software versions V4.24 or earlier.
The WINDOW facility is only used when the BACKUP parameter is set
to WIN. This enables you to restrict the days, or time period within a day
when your KBU 64 can initiate a backup to the ISDN line. Up to 4
backup times (or slots) can be set for each day as required.
The factory settings have the first slot on all days set to 00:00 24:00 and
the remaining slots set to 00:00 00:00. This enables BACKUP on all
days without any restriction.