Configuration Commands
80-10100000-09
4–25
To display CLID numbers of the active channel which have been stored
under the calling line identification security system:
1> CLID[CR]
Stored B1 CLIDs:
1
0793123456
2
09901234311
etc.
If you want to view a CLID number which has been stored in a specific
location, add the number of that location after the CLID command:
1> CLID 26
[CR]
Stored B1 CLID:
26
0123456789
To view the CLID numbers held within a range of store locations, follow
the CLID command with the first and last numbers of the required range:
1> CLID 68 70
[CR]
Stored B1 CLIDs:
68
1123455789
69
00211245541
70
0112245612
If you want to view stored CLID numbers of the non active channel (in
this example, channel 2), first activate channel 2 followed by the CLID
command.
2> CLID XX XX
[CR]
4.13.6 Connecting the USER Port to an Answered Backup
Call
When Talkwire is used (which is the normal use), the calling KBU 64 will
issue commands to the called KBU 64 to connect it’s USER port to the
ISDN.
The CONNECT parameter should normally be set to MANual, as the
incoming commands provide Talkwire controlled connection.