7.4
Adjustment of the Stopper for Blow on Mode
i
Note!
For operation mode "Blow on" only!
The operation mode "Blow on" allows labelling without contact.
The pad does not press on the product. The label will be blown from the pad to the product over a distance
up to 10 mm.
!
Attention!
Switch off the printer and close the shutoff valve for the compressed air at the service unit!
3
4
5
6
7
1
2
8
1. Place a product sample (7) at the labelling point.
2.
Pull the tubes out of the push-in-fittings (3,5).
3. Loosen the screw (2) in the stopper (1).
4. Move the pad manually in the required labelling position.
The distance between the blow pad (6) in the labelling
position and the product surface (7) must not
exceed 10 mm.
5. Move the stopper (1) against the guide block (4) and
tighten the screw (2)
6.
Insert the tubes into the appropriate push-in-fittings (3,5).
7. Open the shutoff valve and switch on the printer.
i
Note!
To reduce the impact energy of the pad it is
possible to use a stopper with cushioning as
option.
Fig. 21
Adjusting the Stopper
y
x
z