31
8.3
Configuration
Parameters of the Applicator
The configuration parameters of the applicator can be found in the menu
Setup > Machine param.
Parameter
Meaning
Default
Applicator
Configuration parameters of the applicator
> Mode of
oper.
Setting the operation mode
Stamp on, Roll on, Blow on
Stamp
on
> Mode of
appl.
Setting the application mode
Print-Apply
/
Apply-Print
Print-Apply
:
An external start signal begins the printing of a label followed by the
application of that label. After the cycle is complete, the pad waits in
the start position without a label.
Apply-Print
:
A separate signal starts the printing of the first label and the transfer of
that label to the pad.
The start signal applies that label and the next label is printed. The
cycle ends with a printed label on the pad.
Print-
Apply
> Waiting
position
only for Mode of oper.
Blow on
and Mode of appl.
Apply-Print
up
: Pad waits in the start position for the start signal
down
: Pad waits in the labelling position for the start signal
up
> Blow time
only for Mode of oper.
Blow on
The length of time (max. 2.5 s) air is blown for the label transfer
0 ms
> Support
delay on
Sets the delay (max. 2.5 s) for the supporting air after printing start and
switching on the supporting air. The delay prevents turbulence at the
front of the label and, consequently, prevents issues when the label is
being picked up from the printer.
0 ms
> Support del.
off
Setting the switch-off delay (max. 2.5 s) for the supporting air between
the end of label forwarding and switching on the supporting air. The
delay can be useful to separate the rear end of the label from the
backing to avoid flaws and to improve the accuracy of label positioning
270 ms
> Delay time
Delay (max. 2.5 s) between start signal and the start of a labelling
cycle.
Allows the use of product sensors within conveyors systems for
example
0 ms
> Lock time
All start signals coming in after the first start signal are ignored when
they arrive within the lock time.
0 ms
> Peel
position
Shift the position of the dispensed label relative to the dispensing
edge. In the software an extra peel offset value is available. The offset
values from “Peel position“ and from software are added together for
execution.
0.0 mm
> Vacuum
control
Setting the label transfer check from printer to pad and from pad to
product by the vacuum sensor
On
> Hand-over up
Take over the label directly from the dispensing edge with contact
between pad and dispensing edge.
Not applicable for Type 4014/4016
Off
> Cleaning
blow
Activate/Deactivate - air pressure pulses to clean the pad
On
> Vacuum delay
On -
The vacuum will switched on after the end of the label
transport.
Off -
The vacuum will switched on with the start of the label
transport.
Off
Table 5
Applicator parameters
Содержание 4114 Series
Страница 1: ...Made in Germany 4114 4116 Stroke Applicator Service Manual ...
Страница 40: ...40 40 11 Drawings 11 2 Pneumatic Drawing Type 4114 Fig 41 Pneumatic drawing type 4114 ...
Страница 41: ...41 11 Drawings 11 3 Pneumatic Drawing Type 4116 Fig 42 Pneumatic drawing type 4116 ...
Страница 42: ...42 42 11 Drawings 11 4 Label Position Type 4114L 4116L Fig 43 Label position 4414L 4116L ...
Страница 43: ...43 11 Drawings 11 5 Label Position Type 4114R 4116R Fig 44 Label position 4114R 4116R ...