19
6.8
Connecting the Compressed Air
!
Attention!
Adjustments and function control were done with a compressed air value of 4.5 bar.
The applicator operating range is between 4.0 and 6.0 bar.
!
Warning!
When connecting the applicator to compressed air it is considered "IN USE!" Cylinder motion is possible!
Do not reach into the zone of the moving pad and keep long hair, loose clothes, and jewelry away.
2
1
3
4
1 Check that the stop valve (2) is closed as
illustrated
2 Attach compressed air to connector (1).
3 Open the stop valve (2) by turning it into the
direction of air flow.
4 Switch on the printer by the power switch.
It is possible to use an air pressure regulation
unit.
cab offers two versions of air pressure regulators.
•
Air pressure regulation unit with included
magnetic valve (3)
Controlling via printer
Interface description of the printer
•
Standard version (4)
Fig. 13
Compressed air connection
i
Note!
If the pad is not in the start position when the printer is switched on an error message appears on the
display.
Press the pause button on the printer.
The applicator will move into the start position and will be ready for use.
i
Note!
Only mount the air pressure regulation unit as illustrated otherwise the functionality of the air-water
separator cannot be guaranteed.
Содержание 4114 Series
Страница 1: ...Made in Germany 4114 4116 Stroke Applicator Service Manual ...
Страница 40: ...40 40 11 Drawings 11 2 Pneumatic Drawing Type 4114 Fig 41 Pneumatic drawing type 4114 ...
Страница 41: ...41 11 Drawings 11 3 Pneumatic Drawing Type 4116 Fig 42 Pneumatic drawing type 4116 ...
Страница 42: ...42 42 11 Drawings 11 4 Label Position Type 4114L 4116L Fig 43 Label position 4414L 4116L ...
Страница 43: ...43 11 Drawings 11 5 Label Position Type 4114R 4116R Fig 44 Label position 4114R 4116R ...