Regulation of the phase shift time when closing (TDMC)
In gates that have a profile (figure 24 - part.A), a phase shift time must be set between movements in order to prevent contact
between the leaves.
In the opening phase, the motor connected to clamp M1 always starts 3 seconds before the motor connected to clamp M2.
In the closure phase, the motor connected to clamp M2 starts before the motor connected to clamp M1. This phase shifting
can be regulated by the parameter TDMC
1
Press the [PGM] button to access programming or if the control unit is already in the programming
menu, press [
5
] until the TDMC function is displayed.
PMOT
Tdmc
2
Press the [PGM] button to enter the TDMC regulation.
The display shows the current value of the TDMC parameter.
Use the [
5
] key to select one of these values:
0 No phase shifting
1 Phase shifting of 5 seconds (default)
2 Phase shifting of 10 seconds
3 Phase shifting of 15 seconds
4 Phase shifting of 20 seconds
0001
0004
3
Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
To go back to the programming menu, press the [PGM] and [
5
] buttons at the same time.
To exit programming, remove the power supply or wait for 60 seconds.
PGM+
5
Step-by-Step functioning mode (PP)
It is possible to select two different modes of the Step-by Step command sent from the transmitter or the key selector.
Every time the button is pressed in the default mode, the following progression of commands is performed cyclically:
OPEN>STOP>CLOSE>STOP>OPEN> and so on.
The sequence can be modified by eliminating the intermediate STOP commands: OPEN>CLOSE>OPEN> and so on.
1
Press the [PGM] button to access programming or if the control unit is already in the programming
menu, press [5] until the PP function is displayed.
PMOT
PP
2
Press the [PGM] button to enter the PP regulation.
The display shows the current value of the PP parameter.
Use the [
5
] key to select one of these values:
ON OPEN>CLOSE>OPEN functioning
OFF OPEN>STOP>CLOSE>STOP>OPEN> functioning (default)
on
off
3
Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
To go back to the programming menu, press the [PGM] and [
5
] buttons at the same time.
To exit programming, remove the power supply or wait for 60 seconds.
PGM+
5
Pre-flashing functioning mode (Pre)
An imminent manoeuvre warning mode can be set through the pre-flashing function.
Once activated, the flashing light switches on 3 seconds before the door starts to move.
1
Press the [PGM] button to access programming or if the control unit is already in the programming
menu, press [5] until the Pre function is displayed.
PMOT
Pre
2
Press the [PGM] button to enter the Pre regulation.
The display shows the current value of the Pre parameter.
Use the [
5
] key to select one of these values:
ON pre-flashing activated
OFF pre-flashing deactivated (default)
on
off
3
Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
To go back to the programming menu, press the [PGM] and [
5
] buttons at the same time.
To exit programming, remove the power supply or wait for 60 seconds.
PGM+
5