42
42
42
42
42
GB
GB
GB
GB
GB
W
W
W
W
Warr
arr
arr
arr
arranty
anty
anty
anty
anty
If the product malfunctions during the warranty pe-
riod, please contact your contract partner, the in-
stallation company, and indicate the model type and
production number (see Technical specifications or
the type plate on the unit).
Operator responsibilities
Operator responsibilities
Operator responsibilities
Operator responsibilities
Operator responsibilities
You have purchased a product that is durable and
easy to service.
However, all technical equipment requires regular
servicing in order to guarantee optimal functionality.
Keep yourself up to date with regard to the quality
and pressure ratio of the water which is to be treated.
If the water quality changes, the settings may need
to be changed. Consult a specialist if this is the case.
Hygienic cleaning of brine container cabinet at least
once per year
Regular chec
Regular chec
Regular chec
Regular chec
Regular checks b
ks b
ks b
ks b
ks by the oper
y the oper
y the oper
y the oper
y the operator are required f
ator are required f
ator are required f
ator are required f
ator are required for
or
or
or
or
the w
the w
the w
the w
the warr
arr
arr
arr
arranty and proper functioning of the unit.
anty and proper functioning of the unit.
anty and proper functioning of the unit.
anty and proper functioning of the unit.
anty and proper functioning of the unit.
In accordance with DIN 1988 part 8 appendix B,
the unit must be inspected regularly or, at the lat-
est, every 2 months depending on service and op-
erating conditions.
Chec
Chec
Chec
Chec
Checks
ks
ks
ks
ks
The oper
The oper
The oper
The oper
The operator m
ator m
ator m
ator m
ator must regular
ust regular
ust regular
ust regular
ust regularly perf
ly perf
ly perf
ly perf
ly perfor
or
or
or
orm the f
m the f
m the f
m the f
m the follo
ollo
ollo
ollo
ollow-
w-
w-
w-
w-
ing chec
ing chec
ing chec
ing chec
ing checks to guar
ks to guar
ks to guar
ks to guar
ks to guarantee that the unit functions
antee that the unit functions
antee that the unit functions
antee that the unit functions
antee that the unit functions
proper
proper
proper
proper
properly
ly
ly
ly
ly.....
Chec
Chec
Chec
Chec
Check the regener
k the regener
k the regener
k the regener
k the regenerativ
ativ
ativ
ativ
ative and refill after use
e and refill after use
e and refill after use
e and refill after use
e and refill after use
Chec
Chec
Chec
Chec
Check the w
k the w
k the w
k the w
k the water hardness
ater hardness
ater hardness
ater hardness
ater hardness
The hardness of drinking water and the set hard-
ness of the blended water must be checked once a
month and corrected if need be (see Start-up).
Chec
Chec
Chec
Chec
Check f
k f
k f
k f
k for leaks
or leaks
or leaks
or leaks
or leaks, visual inspection
, visual inspection
, visual inspection
, visual inspection
, visual inspection
Check connection lines and connections for leaks.
Check for dirt in the regenerative storage area and
brine cavity every 2 months and clean and flush with
clear water if necessary.
The intervals between checks are recommended
minimums and must be reduced accordingly for
sensitive consumer systems.
W
W
W
W
Wear
ear
ear
ear
earing par
ing par
ing par
ing par
ing parts m
ts m
ts m
ts m
ts must also be replaced within the
ust also be replaced within the
ust also be replaced within the
ust also be replaced within the
ust also be replaced within the
prescr
prescr
prescr
prescr
prescribed maintenance inter
ibed maintenance inter
ibed maintenance inter
ibed maintenance inter
ibed maintenance interv
v
v
v
vals in order to
als in order to
als in order to
als in order to
als in order to
guarantee functionality and fulfil the warranty
guarantee functionality and fulfil the warranty
guarantee functionality and fulfil the warranty
guarantee functionality and fulfil the warranty
guarantee functionality and fulfil the warranty
conditions
conditions
conditions
conditions
conditions..... In accordance with DIN 1988 part 8
appendix B, the unit must be serviced once a year.
Communal units must be serviced twice a year.
W
W
W
W
Wear
ear
ear
ear
earing par
ing par
ing par
ing par
ing parts:
ts:
ts:
ts:
ts:
Retainer seals
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
Check non-return valve
Once a year
Check brine valve
Once a year
Check electrolysis cell
Once a year
Check water meter
Once a year
Check low salt level
Once a year
Check drive motor
Once a year
Chec
Chec
Chec
Chec
Check/clean/replace
k/clean/replace
k/clean/replace
k/clean/replace
k/clean/replace
Retainer seals
Once a year
2 pistons (POM) in the brine valve*
Once a year
Float housing*
Once a year
Float cover*
Once a year
Injector
Every 5 years
Electrolysis cell
Every 5 years
Water meter
Every 5 years
Brine valve
Every 5 years
Waste water hose
Every 5 years
Non-return valve
Every 5 years
Blending unit
Every 5 years
Double valve incl. containers
Every 10 years
* Replacement only required if Sanisal/Sanitabs are
exclusively used.
Wearing parts may only be replaced by qualified
personnel (fitters or after-sales service team).
We recommend that you enter into a mainte-
nance agreement with your fitter or the after-
sales-service team.