1
GasAlertQuattro
Introduction
Introduction
The Quick Reference Guide provides basic information to
operate the GasAlertQuattro gas detector. For complete
operating instructions, refer to the
GasAlertQuattro User
Manual
. The GasAlertQuattro gas detector (“the detector”) is
designed to warn of hazardous gas levels above user-defined
alarm setpoints.
The detector is a personal safety device. It is your responsibility
to respond properly to the alarm.
Note
: The detector is shipped with English as the
default displayed language. Additional languages
provided are French, German, Portuguese, and
Spanish. The screens for the additional languages
are displayed on the detector and in the
corresponding Quick Reference Guide.
Zeroing the Sensors
To zero the sensors, refer to steps #1-3 in
Calibration on
page 10
.
Safety Information - Read First
Use the detector only as specified in this Quick Reference
Guide and the User Manual, otherwise protection provided by
the detector may be impaired. Read the following
Cautions
before using the detector.
a
CAUTION
•
Warning:
Substitution of components may impair
Intrinsic Safety.
• Before using the detector, refer to
Sensor Poisons and
Contaminants on page 8
.
• Protect the combustible sensor from exposure to lead
compounds, silicones, and chlorinated hydrocarbons.
Although certain organic vapors (such as leaded
gasoline and halogenated hydrocarbons) may
temporarily inhibit sensor performance, in most cases
the sensor will recover after calibration.
• Caution: For safety reasons, this equipment must be
operated and serviced by qualified personnel only. Read
and understand the User Manual completely before
operating or servicing.
• If using the detector near its upper or lower operating
temperature, BW Technologies by Honeywell
recommends zeroing or activating the detector in that
environment.
• Charge the detector before first-time use. BW
recommends the detector be charged after every
workday.
• Do not use an external power supply or charger to
operate the detector for periods greater than 24 hours. If
powering from an external source, power cycle the
detector once every 24 hours to ensure proper
operation. To power cycle the detector, press and hold
C
until OFF is displayed. Release
C
, then press and
hold until the detector begins the start-up sequence.
Содержание GasAlertQuattro 1
Страница 1: ...Quick Reference Guide 1 2 3 and 4 Gas Detector ...
Страница 4: ......
Страница 11: ...7 GasAlertQuattro Screen Elements Screen Elements ...
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...50104941 536 EN Rev F 2017 BW Technologies by Honeywell All rights reserved ...