GasAlertQuattro
Quick Reference Guide
28
Approvals:
Approved by CSA to both U.S. and Canadian Standards
CAN/CSA C22.2 No. 157 and C22.2 152
ANS/UL - 913 and ANSI/ISA - S12.13 Part 1
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules and ICES-003 Canadian EMI
requirements. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
European Performance Approval
Special conditions for safe use
To comply with ATEX performance approval requirements, the
detector must be operated in the following manner:
Operating manual:
Read and understand the operating
manual. It is essential that the instructions for correct use are
followed.
Instrument power-up:
The instrument must be powered up in
a safe area that is free of hazardous gas and in an atmosphere
of 20.9% oxygen. The detector must be turned on and verified
to be operating in the normal measurement mode before it can
be brought into a hazardous area.
Low-battery alarm:
In the event of a low-battery alarm, the
user must leave the hazardous area immediately.
Operating environment
: The operating environment ranges
that apply for use of the GasAlertQuattro according to ATEX
performance approvals for LEL and oxygen measurements are
shown in
Specifications on page 26
. These specify the climatic
range within which the instrument can be used in conformity to
the performance certifications.
General use:
For use only in potentially explosive atmospheres
where oxygen concentrations do not exceed 20.9% (v/v).
CSA
ATEX
IECEx
BAM
KTL
a.
http://www.honeywellanalytics.com/~/media/honeywell-analytics/
products/gasalertquattro/documents/certificates/
koreanexcertificate_bw_gaquattro_12kb4bo0049.pdf?la=en
Inmetro
Class I, Division 1, Group A, B, C, D
CE 0539
g
II 1 G Ex da ia IIC Ga for Zone 0
Group IIC
KEMA 09 ATEX 0137
EN 60079-0, EN 60079-11, EN 60079-1
Ex da ia IIC Ga IECEx CSA 09.0006
IEC 60079-0, IEC 60079-11, IEC 60079-1
BAM 11 ATEX 1102 X EN 60079-29-1
(for 0 up to 100% LEL methane)
BAM/ZBF/005/15 EN 50104
(for 0 up to 25% v/v oxygen)
BAM EN 50271:2010 (without Clause 4.8, SIL 1
assessment)
BAM/ZBF/010/12 EN 45544
12-KB4BO-0049
a
Ex
da
ia IIC Ga DNV 12.013
3
Содержание GasAlertQuattro 1
Страница 1: ...Quick Reference Guide 1 2 3 and 4 Gas Detector ...
Страница 4: ......
Страница 11: ...7 GasAlertQuattro Screen Elements Screen Elements ...
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ...50104941 536 EN Rev F 2017 BW Technologies by Honeywell All rights reserved ...