35
GasAlertQuattro
Troubleshooting
LCD display freezes
An external power supply or
charger has been used to
operate the detector for periods
of time greater than 24 hours.
If powering from an external source, power cycle the detector once every
24 hours to ensure proper operation. To power cycle the detector, press
and hold
C
until OFF is displayed. Release
C
, then press and hold until
the detector begins the start-up sequence.
a
WARNING
Do not use an external power source or charger to operate the
detector in a hazardous environment. The chargers intended for
use with the GasAlertQuattro detector are not certified for use in
hazardous or potentially explosive environments.
Charging
Battery has been
charging for 6 hours.
Charging indicator on
LCD shows the battery
is still charging.
Battery is trickle charging.
Battery is fully charged and is ready for operation.
Battery indicator does
not display when
charging.
Battery is depleted below normal
levels
Charge the battery for 8 hours. If the battery indicator does not light after
charging, contact BW Technologies by Honeywell.
Problem
Possible Cause
Solution