BÜTTNER ELEKTRONIK – power line pure sinewave inverter
EN
27
2 Appropriate use
The black signal cable must be connected
to batt ery minus (Ground). Please check
above drawings for diff erent applicati ons.
To acti vate the 12 V signal switching
input, the device main switch must be set
to REMOTE positi on.
Connected devices with faulty or
damaged cables must not be operated
on the inverter, represent a potential
safety risk and need to be withdrawn
from circulation.
Warning!
!
!
Direct supply of 230 V consumers
at the inverter
All units off er a power outlet
❶
or direct
connecti on of the 230 V AC consumer.
REMOTE
ON
OFF
POWER
CHECK
❶
Connecting to Output voltage /
Mains voltage output
The output of the inverter supplies
230 V AC sinewave voltage of 50 Hz. The
contact and touching of this voltage is
life-threatening and all safety regula-
tions must be applied similar to local
installed mains supplies !
Warning!
!
!
Before any work on the 230 V AC wiring
or on the inverter, assure to switch off
all voltage connections and check for
absence of any voltage on the 230 V AC
side! Ensure that there is no accidental
switching On of the inverter or plugging
in of mains voltage is possible!
!
Att enti on!
!
!
+ 12 V
external
switch
Control with positive switching
voltage e.g. MT 5000 iQ
+ 12 V
Control with switching
cover to ground
red
black
red
black
red
black