burster Italia s.r.l. · Sede legale ed operativa · Via Cesare Battisti, 16/18 · 24035 Curno (BG) · Tel. +39 035 618120 · Fax +39 035 618250
e-mail: [email protected] · http://www.burster.it
C.F. e P.IVA 11048400151 · Capitale sociale Euro 49.920,00 · R.E.A. di Bergamo 276749
Apparecchi di misura di precisione. Sensori e Sistemi
per grandezze elettriche, termiche e meccaniche
Nominal Torque
Screw
Quantity
Thread depth
Tightening torque
50 / 100 N·m
M 6
8
12 mm
14 N·m
200 N·m
M 8
8
12 mm
35 N·m
500 / 1000 N·m
M12
8
12 mm
120 N·m
Caution!
At alternating torque, the flange connection screws must absolutely be secured with
screw locks. Otherwise the connection screws may loosen.
The used screws may not be too long:
Shunt of the torque measurement
Flange connection is not twist-protected
Then remove the 3 fixing plates and control the position of shaft to stator:
a) Axial alignment of the shaft
b) Evenness of the air gap (shaft may not grind at the stator)
4.2
Stator Assembly
Use keyway for the axial alignment
Align stator to shaft
Rotor may not touch the stator
Note the axial position of rotor to stator
Tolerance: ± 0,5 mm
Tighten screws with a torque wrench.
Use suitable washers, if necessary.
Strength:
8.8
Tightening torque:
24 N·m
2x M8
2x M8
Keyway