32
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Table 7
Possible error codes
Displayed on
controller screen
Code
Problem
causes
Problem
solution
“No fuel” icon
is on
----
Appears upon lack of fuel
Fill up the fuel bunker.
Restart controller from the
ON/OFF key.
“Cleaning” icon
flashes
“Cleaning” icon
is on
А003
----
Firebox or flue are polluted and
need cleaning.
Excess ash or unburned fuel in
the firebox.
Check and clean the fire
-
box or contact your install
-
er to
clean the flue.
Икона “Сервиз”
премига
А004
Controller battery low on charge
Contact your service for
replacement.
Икона “Сервиз”
премига
А005
Fan encoder fault
Contact your service.
Икона “Сервиз”
премига
А007
Boiler door open longer than 1
minute in operation mode
Close the door and restart
the boiler from the ON/
OFF key.
“Service” Icon
is on
Е001
Display screen error
Contact your service.
“Service” Icon
is on
Е004
Display-controller communica-
tion error
Contact your service.
“Service” Icon
is on
Е101
Ignition failed, high temperature
in the water jacket of the boiler
Contact your service.
“Service” Icon
is on
Е102
The chimney, the intake air pipe
or the boiler burner are blocked.
Contact your service.
“Service” Icon
is on
Е106
Defective or non-contacting
buffer sensor.
Contact your service.
“Service” Icon
is on
Е108
Overheating of the boiler or
back burning.
Restart the STB thermo
-
stat on the rear panel.
“Service” Icon
is on
Е109
Open door sensor error
Contact your service.
“Service” Icon
is on
Е110
The room temperature sensor is
defective / not connected.
Contact your service.
“Service” Icon
is on
Е111
The exhaust sensor is defective
/ not connected.
Contact your service.
“Service” Icon
is on
Е113
Excessively high exhaust
temperature. Boiler cleaning is
required.
Contact your service.
“Service” Icon
is on
Е114
Ignition failed. Check the fuel
level.
Contact your service.
Содержание Pell Easy 20
Страница 2: ...2 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 26: ...26 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 28: ...28 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE 10 2 Controller Menus ...
Страница 29: ...29 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 30: ...30 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 31: ...31 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 46: ...46 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 47: ...47 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 48: ...ISO 9001 2008 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...