9. OPERATION OF BOILER
-User`s training for operation and
maintenance of boiler is performed by
an authorized installer.
Failure to observe the installation
and operating requirements
described in the manual and
the service booklet voids the
warranty.
Protective gloves must be used
9.1.
Operation of boiler
Pell Easy
Ignition.
After starting the boiler up from the control
panel, the main pellet auger conveys
certain amount of fuel in Combustion
chamber. This specific amount of pellets
is set by the installer and depends on the
fuel characteristics. This specific amount
of pellets is being ignited using hot air.
Burning.
The burning process takes place in the
combustion chamber of the boiler, as the
fuel portions are dosed (measured) at
regular intervals by the integrated auger.
This achieves optimum combustion.
The boiler performance is controlled
and operated by a temperature sensor
that measures the temperature of the
water jacket (mantle) and a temperature
sensor that measures the temperature
of the exhaust gases. Ignition and stop
are controlled by the exhaust gas sensor,
which gives information to the control
unit. The power is determined by the
adjusted maximum temperature in the
boiler, as shortly before reaching it, it
starts modulating.
Self cleaning system
.
The boiler has a self-cleaning feature that
allows self-cleaning of the combustion
chamber. At regular intervals, the fan
starts on maximum power to clear the
residual ash in the combustion chamber.
Thus ensuring a long and effective
combustion process.
8. FILLING THE HEATING INSTALLATION
Table 6
Problem
Prevention
Possible installation damage due
to strains in the material caused by
temperature differences
Fill the heating installation only in cold conditions
(inlet temperature must not exceed 40°C).
Danger of installation damage due
to accumulation of deposits
Condensate formation and tar
deposits may shorten boiler’s
operational life.
- Do not operate the heating boiler for a long period
of time in partial load mode
- The temperature at the boiler inlet must not be
less than 65°C, boiler water temperature must be
between 80°C and 85°C.
- Use the boiler for a short period to heat warm
water in the summer.
9. ЕКСПЛОАТАЦИЯ НА КОТЕЛА
Содержание Pell Easy 20
Страница 2: ...2 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 26: ...26 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 28: ...28 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE 10 2 Controller Menus ...
Страница 29: ...29 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 30: ...30 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 31: ...31 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 46: ...46 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 47: ...47 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 48: ...ISO 9001 2008 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...