12
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
combustion, boiler’s output and life span.
The draught created by the chimney
is in functional relation to its cross-
section, height and the roughness of its
interior walls. No other appliance may
be connected to the chimney serving the
boiler. Chimney diameter must not be
smaller than the flue outlet of the boiler.
Flue outlet must be connected to the
chimney opening. In terms of mechanical
properties, the flue outlet must be sturdy
and properly sealed (to avoid gas leak)
and allow for easy access for cleaning
on the inside. The inner section of the
flue outlet must not be greater than the
effective section of the chimney and must
not narrow. Avoid using elbow joints.
The chimney cleaning opening has to be
in its lowest part. The chimney’s wall has
to be three plied where the medium layer
is from mineral wool. The thickness of the
insulation is not less than 30 mm when
the chimney is setting up inside the house
and the thickness is 50 mm, when the
setting up is outside.
Please entrust choosing a chimney and
its installation by a qualified professional.
The required distance between the boiler
and the chimney is 300-600 mm. Draught
regulator
(1)
must be installed at least 600
mm from the joint (connection).
The use of flexible metal tubes
of stainless steel or aluminum
material is forbidden!
T
able 4. Recommended minimum sizes and
chimney draft
Model
Chimney
diameter,
mm
Chimney draft,
Pа
20 kW
Ø 100 мм
8 - 10
35 kW
Ø 100 мм
10 - 15
Содержание Pell Easy 20
Страница 2: ...2 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 26: ...26 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 28: ...28 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE 10 2 Controller Menus ...
Страница 29: ...29 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 30: ...30 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 31: ...31 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 46: ...46 TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE ...
Страница 47: ...47 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL ...
Страница 48: ...ISO 9001 2008 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...