On  no  account  should  glass  mirrors,  picture  frames  or  any  electrical  equipment  e.g.  large 

screen TV’s be fitted or positioned on the wall above the appliance as the heat rising could 
damage them. 

3.7

 

This  appliance  is  intended  as  a  secondary  heat  source.  Check  that  a  primary  source  of  heat 
(such as radiators) is present in the room. If insufficient primary heat is being used there may 
be a build-up of condensation. 

3.8

 

Prevent  use  of  the  appliance  whilst  painting  &  decorating,  as  the  residues  can  lead  to 
unpleasant  smells  from  the  appliance.  Always  cover  or  have  the  appliance  removed  when 
decorating. 

3.9

 

Houses with warm air heating systems, solid walls, or no damp proof course may be unsuitable 
for this appliance. (Consult your supplier) 

3.10

 

 Asbestos is not contained within any part of this appliance

3.11

 

This is a flueless appliance and MUST NOT be fitted into a working flue. Where an old fireplace 
opening is to be used then the flue must be sealed off from the fire. 

4.

 

Gas Supply 

4.1

 

Prior to commencement of the installation, establish that an adequate supply of gas is available. 
If necessary consult the gas supplier. Any new or existing gas pipe work should be checked for 
sufficient  size  to  carry  the  demand  of  this  appliance  and  the  demand  of  other  appliances 
installed. To prevent unacceptable pressure losses, no more than 1.5m of 8mm pipe should be 
used. 

4.2

 

Decide on the gas supply route to be taken up to the appliance location. (Fig 2) 

4.3

 

Before  carrying  out  any work  on  existing or new  pipe  work,  ensure that the  supply  is  isolated 
and disconnected and plug any ends to prevent the entry of debris or the risk of the gas supply 
being restored. 

4.4

 

A concealed gas supply route is required for this appliance. (See Fig 2) 

4.5

 

If the gas pipe passes through a wall, cavity or un-vented void then there should be no joins in 
this area and the pipes should be fully sleeved. Before pushing gas pipes through walls, seal the 
pipe ends to prevent debris entering the pipes. 

4.6

 

An isolating valve must be situated near to the appliance for ease of servicing or in the event of 
a  gas  leak.  The  appliance  gas  inlet  connection  is  only  suitable  for  8  mm  diameter  pipe  with  a 
compression fitting. In the event of a gas leak the appliance must be turned off at the nearest 
isolating valve. 

4.7

 

Before  connecting  the  appliance  fully  purge  all  pipe  work.  CAUTION:  before  purging  open  all 
doors and windows, extinguish all cigarettes and any other naked lights. 

4.8

 

Before  restoring  the  gas  supply,  fully  check  the  system  for  gas  tightness  using  an  approved 
pressure drop test method and suitable leak detection fluid. 

Fig 2 - Gas routes 

 

 

 

 

Содержание ASTUTE G4113

Страница 1: ...HE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 E mail info burley co uk web www burley co uk G4113InstUser G20 31 Issue May2019 TO...

Страница 2: ...tions emits less than 130mg kWh NOx 1 APPLIANCE DATA Refer to the appliance data badge this is located on a hinge out plate ENSURE THAT THE LOCAL CONDITIONS OF USE CORRESPOND TO THE INFORMATION ON THE...

Страница 3: ...fails to establish repeat the process Due to the safe efficient nature of the fire it is not unusual for this to take two or even three attempts The acoustic signal will now cease the gas rate adjust...

Страница 4: ...rn the receiver unit to its original position REPLACE THE HEAT SHIELD over the unit CAUTION With the exception of battery replacement the battery holder must be located within the heat shield at all t...

Страница 5: ...urn slowly anticlockwise to the ignition position A click will be heard and the pilot should light If it does not repeat the operation a few times to purge any air in the pipes Continue to hold knob f...

Страница 6: ...the control lever to the top of its travel 6 The off position on the side of the fire may not correspond exactly with the control lever This is only intended as an indication 1 6 Battery Replacement B...

Страница 7: ...ulations as amended The installation must also be in accordance with the relevant parts of local and national building regulations Failure to have the fire fitted by a qualified person nullifies ALL g...

Страница 8: ...emand of this appliance and the demand of other appliances installed To prevent unacceptable pressure losses no more than 1 5m of 8mm pipe should be used 4 2 Decide on the gas supply route to be taken...

Страница 9: ...ides of the fire box assembly must be removed and replaced with suitable non combustible material such as a rigid non combustible insulating board a minimum thickness of 50 mm rock wool or similar non...

Страница 10: ...ve off fumes when heated and stain fireplace parts decor Use one or a combination of the methods detailed Method A Fixing to the wall or fireplace back panel Note It is not recommended to use this met...

Страница 11: ...ry cavity box fitted The appliance and the proprietary cavity box both have holes in their outside flange and can be secured to the wall as a pair Alternatively the proprietary cavity box can be secur...

Страница 12: ...ls to the top rear and sides of the appliance Any wall coverings should be removed from within the enclosure and any paper backed plaster board on the wall face should be protected or replaced with pl...

Страница 13: ...section 5 7 1 7 With the fire box fitted securely into the opening refit the burner control assembly 7 1 8 Connect the gas supply pipe to the 8mm compression fitting on the inlet pressure test point e...

Страница 14: ...the wall and fit the fire surround Due note shall be taken of the recommendations specified in section 5 7 2 7 Fit the appliance into the recess using the fixing methods detailed in section 6 7 2 8 W...

Страница 15: ...e is flat and slowly push back until it touches the protruding ends of the rear log piece Fig 9 Figure 9 8 1 3 Using photo to identify the correct Y shaped log place log on the left hand side of the f...

Страница 16: ...The top part of the glass panel should be engaged under the front vent panel The vent panel shall then be fixed using the 3 screws 8 3 Fitting the Outlet Grille 8 3 1 Push and hold grille in position...

Страница 17: ...riod of time 10 0 COMMISSIONING AND OPERATION YOU MUST COMPLETELY ASSEMBLE THE FIRE INCLUDING THE GRILLE BEFORE COMMISSIONING BURLEY APPLIANCES IS THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVE...

Страница 18: ...appliance must not be operated with the glass removed 12 0 INSTRUCT THE USER It is important to hand these instructions to the user for safe keeping and future reference The user shall be instructed...

Страница 19: ...ponents These components are extremely fragile Examine the condition and check for signs of damage or cracking Replace if necessary Using suitable respiratory equipment clean the components with a sof...

Страница 20: ...on an annual basis Check for combustion product leakage It is important that the products of combustion produced by this appliance all pass through the two catalysts A very small amount of product le...

Страница 21: ...as Valve VAL1921 Glass GLA4113 Ash Pan Cover ASH4111 Grille GRI4111 USE ONLY GENUINE REPLACEMENT PARTS In certain cases depending on the fault and the part or parts to be replaced Burley Appliances ma...

Страница 22: ...est must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least 20 min...

Страница 23: ...ult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filter...

Страница 24: ...ortant to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties...

Страница 25: ...ear as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe registered ins...

Страница 26: ...ling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up but are...

Страница 27: ...26...

Страница 28: ...fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 756956 Fax 01572 724390 www burley co uk Email...

Отзывы: