1
INTRODUCTION
Thank you for choosing this Burley product. All of our products carry a CE mark which is awarded by an
independent test house (notified body) and shows the fires have been type tested to meet the
essential requirements of the European Gas Appliance Directive and the appropriate British Standards.
An oxygen depletion sensing pilot light is also fitted and will sense any significant oxygen depletion in
the room and shut the fire down safely.
Declaration of Conformity
Burley Magiglo Ltd. declares that the appliance described in “Technical data” conforms to the following
standard(s) BS EN 14829: 2007
Efficiency Declaration
This appliance has a thermal efficiency of 100% giving an Energy Efficiency Index of 91%. Which is
A
rated on all variants/options & emits less than 130mg/kWh NOx.
1.
APPLIANCE DATA
Refer to the appliance data badge (this is located on a hinge-out plate)
ENSURE THAT THE LOCAL
CONDITIONS OF USE CORRESPOND TO THE INFORMATION ON THE DATA BADGE.
Natural Gas G20
Cat I3 LP Gas
Category
I2H
I3P I3+ I3B/P
Supply Pressure mbar
20
37 37 28-30
Inlet Pressure mbar
20
*
37 37 28-30
*
Heat Input (net)
(High)
4.2kW
4.2kW (295g/h)
(Low)
2.5kW
2.5kW (175g/h)
Inlet Connection
8mm Compression
8mm Compression
Injector (remote)
Elbow 92/340
Elbow 92/160
Note -
The inlet pressure must be within +/- 1.0 mbar of specification with
all
gas appliances in the
house switched on and also with just the Burley appliance operating. If outside of tolerance the fault is
most likely to be in the installation pipe work or service governor at the meter. If the problem is the
meter governor, this is the property of the gas service provider (e.g. Transco in the UK or Bord Gais in
Rep. of Ireland) and they should be called to rectify this.