User Guide
259
www.bull.com
Troubleshooting Guide
This section provides you a guide to identify a problem and locate its source.
Warning
The system power and any peripheral devices should be turned
off before connecting or disconnecting peripheral devices to or
from the system.
Otherwise, you could permanently damage the system or
peripheral devices.
1.
Turn off the system and any peripheral devices. Disconnect all external
peripherals from the system, except for the keyboard and monitor. The
system´s power cord must be plugged into a grounded electrical outlet.
2.
Make sure your keyboard and monitor are properly connected to the system.
Turn the monitor on, then adjust its brightness and contrast controls to suit
your preference (see your monitor´s documentation).
3.
Turn the system on. If the power indicator does not light up, but the system
seems to be operating normally, the indicator may need replacement.
4.
Monitor the power-on self test (POST) execution. Each time you turn on the
system, the POST checks the system board, memory, keyboard, and certain
peripheral devices.
5.
Check the following during the POST:
If the POST does not detect any errors, the system should boot up.
Errors that do not prevent the boot process (non-fatal errors) display a message that may appear similar to the following display:
■
(Error Message Line 1)
■
(Error Message Line 2)
■
Press <F1> to continue,
■
<DEL> to enter Setup
■
You should note the error and press
F1
to resume the boot-up process, or
DEL
to enter Setup.
6.
Errors that prevent the boot process from continuing (fatal errors) are
communicated by a series of audible beeps. If this type of error occurs, record
the information and refer to the Error Messages: Beep Codes section.
System Viewers
Monitor the occurrence of fault with the Remote Manager (NEC ESMPRO, ASWM or
another utility, depending on your system) during the system operation.
Especially take note on whether any alert is reported to the Remote Manager on the
management PC.
Содержание NovaScale R410 E1
Страница 1: ...NovaScale T810 E1 T830 E1 R410 E1 User s Guide NOVASCALE REFERENCE 86 A1 15FA 00 ...
Страница 2: ......
Страница 34: ...User Guide 34 www bull com Motherboard Motherboard Layout Figure 14 Motherboard Layout ...
Страница 53: ...User Guide 53 www bull com SAS Hard Disk Drive Capacity 73GB minimum 15000 RPM RAID support ...
Страница 294: ...User Guide 294 www bull com Boot Manager Menu Allows you to boot the system using one of the items listed in the menu ...
Страница 295: ...User Guide 295 www bull com Error Manager Menu The Error Manager Menu displays any errors encountered during POST ...
Страница 318: ......
Страница 319: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 15FA 00 ...