LinkStation User Manual
193
Appendix
Error code Descriptions
E04
The firmware is corrupted. Contact Buffalo technical support for assistance.
E10
The LinkStation is running on the UPS battery due to a power outage. The system
will now be shut down safely. Check that power is being supplied to the UPS, and if
there are no problems, turn on the LinkStation.
E11
An error occurred in the fan speed. Check that no foreign objects or dust are
clogging the fan. If any foreign objects or dust are found, use a pair of tweezers, air
duster, or other tool to remove them.
If the error is displayed again, contact Buffalo technical support for assistance.
E12
System temperature has exceeded the maximum safe value. Do not place objects in
the area around the LinkStation. Also, move the LinkStation to a cooler location.
E15
The bad sectors in the hard drive have reached a dangerous level. Contact Buffalo
technical support for assistance.
E16
Unable to find the hard drive. The drive may be disconnected or may have failed.
Contact Buffalo technical support for assistance.
E22
Mounting of hard drive failed. Format the hard drive. After formatting and rebooting,
if the error still appears, contact Buffalo technical support for assistance.
E30
The hard drive may be damaged. Contact Buffalo technical support for assistance.