E14
The RAID array cannot be mounted. Run the RAID array disk check in the
LinkStation's Web Admin interface.
E15
The bad sectors in the hard drive have reached a dangerous level. Replace the hard
drive indicated by the red Status LED.
E16
Unable to find the hard drive. Hard drive may be disconnected or may have failed.
After shutting down, reinstall the hard drive.
E22
Mounting of the hard drive failed. Format the hard drive. After formatting, if the error
still appears after rebooting, replace the hard drive. If the error is displayed again,
contact Buffalo technical support for assistance.
E23
An error occurred, so the hard drive was removed from the RAID array. Replace the
hard drive indicated by the red Status LED.
E30
The hard drive may be damaged. Replace the hard drive indicated by the red Status
LED.