Appendix
6
Installation and servicing instructions condensing gas boiler 800 - 24/29/43/60 and 800 - 24T25/29T25 H/V • edition 02/2006
59
Subject to modifications resulting from technical improvements !
Buderus • http://buderus-domestic.co.uk
6
Appendix
6.1
Technical data
Size
Unit
800 – 24
800 – 24T25
H/V
800 – 29
800 – 29T25
H/V
800 – 43
800 – 60
Type of gas category as per EN 437
Great Brittain
GB II
2H3P
20 mbar (natural gas
H
); 37 mbar (LPG)
GB I
2H
20 mbar
(natural gas
H
)
Rated thermal load
G20
[kW]
[Btu/h]
6.6 – 22.0
22,520 – 75,060
6.6 – 22.0
22,520 – 75,060
8.4 – 28.0
28,660 – 95,540
8.4 – 28.0
28,660 – 95,540
12.1 – 40.2
41,285 – 137,162
22.0 – 56.5
75,064 – 192,778
Rated heating capacity
Heating curve 75/60
°
C
Heating curve 40/30
°
C
[kW]
[Btu/h]
[kW]
[Btu/h]
6.4 – 21.4
21,840 – 73,020
7.0 – 23.4
23,880 – 79,840
6.4 – 21.4
21,840 – 73,020
7.0 – 23.4
23,880 – 79,840
8.2 – 27.3
27,980 – 93,150
8.8 – 29.9
30,030 – 102,020
8.2 – 27.3
27,980 – 93,150
8.8 – 29.9
30,030 – 102,020
11.8 – 39.3
40,260 – 134,090
12.9 – 42.9
44,015 – 146,375
21.4 – 55.1
73,016 – 188,000
23.7 – 60.0
80,865 – 204,720
Seasonal efficiency (SEDBUK)
%
90.0
90.4
90.1
90.5
90.3
90.2
Boiler efficiency
Heating curve 75/60
°
C (max. capacity)
Heating curve 40/30
°
C (min. capacity)
[%]
[%]
97.3
107.0
97.3
107.0
97.5
107.1
97.5
107.1
97.8
107.0
97.6
107.1
Stand-by heat losses
[%]
0.60
0.50
0.50
0.50
0.40
0.34
Central heating installation
Min. circulation water volume
[
l
/
h
]
150
150
225
225
300
500
Heating water temperature
[°C]
40 - 80
40 - 80
40 - 80
40 - 80
40 - 80
40 - 80
Δ
T at residual head of 200 mbar
[K]
approx. 15
approx. 18
approx. 18
approx. 18
approx. 22
approx. 20
Max. operating overpressure boiler
[bar]
3
3
3
3
3
3
Volume heat exchanger heating
circuit
[l]
2.5
2.5
3.0
3.0
3.6
4.7
Pump over-run time
Position 1
Position 2
[min]
[h]
4
24
4
24
4
24
4
24
4
24
4
24
Hot water circuit combination boilers
Volume hot water reservoir
[l]
–
25
–
25
–
–
Max. operating overpressure
hot water reservoir
[bar]
–
8
–
8
–
–
Pump over-run time following
domestic hot water mode
[min]
–
2
–
2
–
–
Domestic hot water flow rate
at 60 °C
[
l
/
min
]
–
6.0
–
8.0
–
–
Stand-by heat losses in hot
water mode in 24 hours at
WW (DHW)
temp
= 60 °C
[kWh]
–
approx. 1.6
–
approx. 1.6
–
–