LRV-1 lift control valve
1 General, product description
31/86
300-I-9010050-E-28/02.2012
1.9
IWK-1 feedback cable
Note:
The feedback cable must be run from the lift control valve directly
to the NTA‐2 power supply unit without any intermediate terminals. Any
discontinuity in the feedback cable (break, kink, etc.) can endanger
trouble-free operation.
It is essential that connection 2 is ground-bonded to terminal 12,
otherwise the zero point of the sensor will not be stable.
If you cut the cable to length and terminate it yourself, be sure to wire it
correctly in accordance with the following diagram:
BN
GN
WH
YE
Legend
A
B
C
D
Line socket with PG7 gland
NTA-2 connector
WAGO plug
Screen
E
F
G
H
15V
Signal 0
…
±13.4V
Supply –15V
Ground
Colours
BN
GN
brown
green
WH
YE
white
yellow
1.10
Surroundings
For reliable operation, the following conditions must be maintained in
the surroundings:
Surroundings
Requirement
Machine room
temperature
2
…
40
°
C
Oil temperature
0
…
70
°
C*
Relative air humidity
max. 90% (non-condensing)
* The permissible temperature range is determined by the permissible
viscosity range. For detailed information,
⇒
page83, chapter6.2.
1.11
Emissions
The following emissions can occur during operation:
Emission
Corrective action / Note
Heat
Ensure fresh-air supply and warm-air extraction
Noise
Sound-proof the entrance to lift shaft (noise transmission)