LRV-1 lift control valve
35/86
300-I-9010050-E-28/02.2012
3.2
Display of the operating status
Legend for the LEDs
1 RUN
Ready for operation (green). Lights when ready for travel; off during
parameterisation
2 UP
UP travel (yellow). Lights during upwards travel (fast and slow)
3 DOWN
DOWN travel (yellow). Lights during downwards travel (fast and slow)
4 ERROR
Fault indication (red). Lights when a fault has occurred; no travel is
possible
5 SIU-1
SIU-1 display (yellow). Lights when the permissible demand/feedback
difference is exceeded
6 RELAY
Relay display (yellow). Lights when the relay on power supply unit
actuates because of a fault,
⇒
3.3
Miniterminal
Keys
1
Demand values menu
2
Options menu
3
Zero point display
4
Menu - Information
↑
Steps to previous parameter
↓
Steps to next parameter
+
Increases the value of the
current parameter
-
Decreases the value of the
current parameter
E
When parameter value is displayed:
back to parameter selection;
in parameter selection mode:
quits parameterisation mode
↵
Pipe-rupture valve test
General description
S
Commands are displayed during travel
S
Zero-point adjustment
S
Fault memory can be called up
Operating controls and indicators