LRV-1 lift control valve
36/86
300-I-9010050-E-28/02.2012
Display during travel
During travel the display indicates the status of the command inputs
K1…K8.
For this purpose the command signals are displayed coded as powers
of 2:
S
K1 =
1
S
K2 =
2
S
K3 =
4
S
K4 =
8
S
K5 =
16
S
K6 =
32
S
K7 =
64
S
K8 =
128
If several command signals are present simultaneously, e.g. K3 and K4,
the display indicates the sum of the individual signals:
K3 = 4, K4 = 8, display = 012
With the command input set to Bucher K1..K8 (
⇒
values will be displayed:
Travel
command
Command
signal
Additional command signals
none
(normal
travel)
Inspection
speed
Auxiliary speed
—
K5
K6
K7
K8
none
0
16
32
64
128
Slow UP
K2
2
18
34
66
130
Fast UP
K1 + K2
3
19
35
67
131
Slow DOWN
K4
8
24
40
72
136
Fast DOWN
K3 + K4
12
28
44
76
140
Description of function
S
By pressing any of the keys 1 to 4 for at least 2seconds, the
DELCON switches into parameterisation mode. No travel is possible;
the green RUN LED on the DELCON goes out.
S
Select the desired parameter using the
↑
or
↓
key
Note:
The parameter names of the menu Options (2) do not appear in
numeric order of sequence, but in the order of sequence as shown in the
parameter overview,
⇒
page64, chapter5.2
S
Display value with + or – key
S
Increase value with + key, decrease value with – key
S
With
↑
or
↓
key, save the value and return to parameter selection
S
With key E, do not save the value and return to parameterisation
mode
S
Press the key E again to quit parameterisation mode
Operating controls and indicators