DIAPER FEEDER Device
MATRIX CUBE
- 87 -
Example 3:
Final tension = 4 g
Initial tension = 10 g
N = 100
Choose the desired value using:
(to increase the value)
or
(to decrease the value).
to confirm.
P2.4
K-PID
This parameter represents a multiplier that affects the control algorithm depending
on the yarn elasticity characteristics.
[Allowed values 1 ÷ 5] (1 = Rigid Yarn…… 5 = Elastic Yarn)
Choose the desired value using:
(to increase the value)
or
(to decrease the value).
to return to the beginning of P2 menu.
to switch to P3 menu.
to return to CONTROL status without programming P3 and P4 menus.