Sign Off Procedure at System Reception
MATRIX CUBE
- 102
5
Connect the MATRIX CUBE Terminal cable to the
electrical panel of the Creel.
6
Connect the CN.X8.001 junction board to the
electrical panel of the Creel and to the TS55 sensors
7
Open the electrical panel
Power on the electrical panel of the Creel connecting
a Three-phase + Ground supply line to the R,S,T
and PE terminal clamps, the relevant cable gland.
This operation must be carried oput by a
specialized technician, in compliance with the
local safety regulations in force.
Close the electrical panel
8
Power on the system turning the main switch of the
electrical panel to position ON and confirm that the
display of MATRIX CUBE Terminal and the displays
of DIAPER FEEDER Devices show the initial screen.