Installation and Connections
MATRIX CUBE
- 12 -
IS3.. Sensor (spool change detection) Technical Characteristics
Power supply voltage
12 .. 24 Vdc ± 20%
Absorption 15
mA
(max 20 mA)
STOP output
NPN
STOP output protection
Protection against over-voltages/short-
circuits
Maximum Current of STOP output
200 mA continuous; 500 mA pick
Reaction Delay
Programmable from 5 to 1000 msec
Sensitivity Programmable
(10 levels)
Signaling
With integrated LEDs
Dimensions
(mm)
25 x 10 x 36.3
Operating temperature range
10° - 60 °C
Storage temperature
-25° - +85° C
TS55 Sensor Technical Characteristics
Power supply voltage
12 .. 24 Vdc ± 10%
Absorption 20
mA
(max)
Operating temperature range
10° - 50 °C
Storage temperature
-25° - +85° C
Tension range
0 - full scale
Useful tension range
0% - 95% full scale
Max applicable tension
10 times the full scale value
Drift error
0.05% / °C
Repeatability error
0.5%
Max linearity error
2% (0 - full scale)
Содержание MATRIX CUBE
Страница 1: ...MATRIX CUBE Operating Manual ENGLISH Rev 4 2 April 2014 ...
Страница 3: ...Introduction i ...
Страница 4: ......
Страница 10: ...Introduction MATRIX CUBE vi Page intentionally left blank ...
Страница 13: ...Installation and Connections 1 ...
Страница 14: ......
Страница 40: ...Installation and Connections MATRIX CUBE 26 Page intentionally left blank ...
Страница 41: ...Operating Instructions 2 ...
Страница 42: ......
Страница 87: ...Error Messages 3 ...
Страница 88: ......
Страница 91: ...DIAPER FEEDER Device 4 ...
Страница 92: ......
Страница 117: ...Maintenance of MATRIX CUBE System 5 ...
Страница 118: ......
Страница 123: ...Sign Off A ...
Страница 124: ......
Страница 128: ...Sign Off Procedure at System Reception MATRIX CUBE 104 Page intentionally left blank ...