Installation and Connections
MATRIX CUBE
- 10 -
1.8 DIAPER FEEDER Interface
TS44
Connector for TS44 tension sensor connection
SM/IN - SM/OUT Connectors for DIAPER FEEDER devices daisy chain connection
EXT
Connector available for future expansions
UNICO
Connector for intelligent accessory connection
IS3..
Connector for spool change sensor connection
DIAPER FEEDER Device Technical Characteristics
Power supply voltage
24 VDC ± 10% or 24 VAC ± 20%
0.2 A
(during normal operation)
1 A
(under stress)
Maximum absorption
3 A
(at start-up)
STOP Outputs: relay contacts (NO)
0.3 A 125 VAC
1 A 30 VDC
Opto-insulated Inputs
0-24 VDC
VIL Max 1.2 VDC
VIH Min 5 VDC
Max. voltage (
Inputs/Output)
30
VDC
Programmable yarn tension
0.5
÷ 100.0 gr. (resolution 0.1 gr.) or
5 ÷ 1,000 gr. (resolution 1 gr.)
Depending on the type of TS44 sensor used
Programmable alarms
0.1 ÷ 10 sec.
Integrated keypad
3 push-b STOP red LED
Signaling
With LCD graphic display
Dimensions
290 x 86 x 94 mm
Operating temperature range
10° - 60 °C
Storage temperature
-25° - +85° C
Tension range
0 / full scale
Useful tension range
0% - 95% full scale
Max applicable tension
10 times the full scale value
Содержание MATRIX CUBE
Страница 1: ...MATRIX CUBE Operating Manual ENGLISH Rev 4 2 April 2014 ...
Страница 3: ...Introduction i ...
Страница 4: ......
Страница 10: ...Introduction MATRIX CUBE vi Page intentionally left blank ...
Страница 13: ...Installation and Connections 1 ...
Страница 14: ......
Страница 40: ...Installation and Connections MATRIX CUBE 26 Page intentionally left blank ...
Страница 41: ...Operating Instructions 2 ...
Страница 42: ......
Страница 87: ...Error Messages 3 ...
Страница 88: ......
Страница 91: ...DIAPER FEEDER Device 4 ...
Страница 92: ......
Страница 117: ...Maintenance of MATRIX CUBE System 5 ...
Страница 118: ......
Страница 123: ...Sign Off A ...
Страница 124: ......
Страница 128: ...Sign Off Procedure at System Reception MATRIX CUBE 104 Page intentionally left blank ...