Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
25/73
Osc. Params Add-on – Additional functions for oscillation
(can only be used for the sensor oscillation)
Additional specifications can be set for the sequence of the
oscillation in this sub-menu.
1. Select the sub-menu
Osc. Params Add-on
and
confirm with ENTER.
2. The parameters displayed in the setting menu have the
following meanings:
►
start/stopp at act.pos:
When the function is activated, the
oscillation will continue at the position
where it was stopped.
►
start osc. after restart:
When the function is activated, the
oscillation is immediately started when
the system is switched back on.
B 3.6 Save settings
Once the parameters have been determined for the current system,
they can be saved. This enables the facility to access them again at
any time in the case that modifications have been carried out
unintentionally or by unauthorized persons.
1. Press the
MENU
button.
The Setup menu appears in the display.
2. Select
Save/Load Settings
menu and press ENTER.
3. Saving or loading the settings can now be carried out using
keys
F2
or
F3
.
F2 = Save the entered setting
F3 = Load saved values
4. Press the
ESC
button to exit the window.
Attention!
This setting cannot be copied to another
controller or saved externally.
Oscillation Add-on: